Unmatched Process Control & Flexibility
No matter what the application, PCTHYPERCLEAN™ Megasonic Generators havebecome the standard by which others are measured.No other manufacturer’s generators are able to drivevirtually any make megasonic transducer array. Sowhether a new system or replacement generator isneeded, PCT can provide Process improvement withour patented HYPERCLEAN™ technology.PCT Systems, Inc. offers complete HYPERCLEAN™Megasonic Systems including a wide tank selectionof quartz, plastics and stainless steel for any sizeapplication or substrate. Customizable transducerarrays in either direct bond or indirect transferconfigurations to offer an unequalled selection forusers to optimize their systems.
- Multiplexing operation for 2-8 transducers per output.
- Optional embedded temperature controller for heaters
- Individually Configurable and Tunable for Optimum Process Results
- Programmable RF Output Range up to 350 Watts per Channel
- 2 Independent Channels with 8 outputs per Channel
- Synchronized or Individual Control of Each Channel
- Patented Multiplexing for On/Off Control of Individual Transducers
- Process Variables and Real Time Data Monitoring
- Multiple Frequency Bands Individually Controlled
(600 kHz – 1 MHz)
Dimension | Model 6000 Series Generator |
Width | 14.0” |
Length | 14.0” |
Height | 7.0” |
Megasonic Amplifier Operation | |
Controller | Multiplexing operation for 2-8 transducers per output. Optional embedded temperature controller for heaters. |
Number of Channels | 2 |
Number of Outputs per Channel | 8 |
Maximum RF Output/Channel | 350 watts |
Maximum RF Output per Unit | – |
Programmable RF Output Range | 0 to 350 watts per Channel |
Programmable Recipes / Channel | – |
Frequency Changes / Recipe | – |
RF Output Power Tolerance | +/- 10% |
Frequency Bands | 600Khz-1MHz |
Mechanical Specifications | |
Voltage Rating | 208-240 VAC, 50/60 Hz |
Current Rating | Max 10 amps non-heated (Max 30 amps heated with Model 6000) |
Environmental Operating Range | 0° to 27°C Operating Range, -25° to 50°C Storage Temperature Range |
Frequency Resolution | 100 Hz |
Frequency Accuracy | +/- 100 Hz |
Programmable Sweep Functionality | 1-10 KHz |
RF Output Connectors | DB15F |
External Interface | |
External Interface | DB15 Male Connector, +5v Loopback – Pin 10, Liquid Level – Pin 4, Ground – Pin 8, 9, 12, |
Communication Ports | SECS II: RS232: DB15 Male connector, Receive – Pin 6, Transmit – Pin 7, |
Transducer Connections | DB15 Female connectors for each array/channel |
Displays/User Interface/Data Storage | |
Display | 4 Line 40 Character LCD with keypad or PDA/LCD Touch Screen Monitoring for Frequency vs. Time, Power vs. Time, and more |
Data Storage Capacity | 2 GB |
Data Export | XML Format |